Izdelki za nastaveći dio za astronomske mreže (5)

NOXmatic / NOXtreme CDM - UPORABITI

NOXmatic / NOXtreme CDM - UPORABITI

Since the implementation of the Kyoto treaty in February 2005 the world has seen a widespread development and tightening of regulations governing greenhouse emissions. The Kyoto treaty has provided an incentive for industrialized and developing nations alike to invest in the reduction of emissions. To get the required CO2 certificates out of JI- and CDM projects it is necessary not only to ensure the correct and sustainable treatment of the methane gas according to local regulations, but also to reliably collect and save the data in a manner which inhibits any possible manipulation. ennox delivers the required gas scrubbers, pressure stations, flare and additional measurement and recording components for your JI/CDM- project.
Simulacija CFD, FEM statična in dinamična

Simulacija CFD, FEM statična in dinamična

Simulation, CFD, FEM statisch und dynamisch, Toleranzanalyse, Schwerpunktsimulation, Schattensimulation, - Flow-Simulation (CFD-Simulation) mechatronischer Baugruppen zum Bewerten von Strömungen, Kühlkreisläufen und Temperaturhaushalten - Statik-Simulation, um Kraftverhältnisse, Spannungsverhältnisse und Verschiebungen zu bewerten - Dynamische Simulation, Fallprüfung, Schlagprüfung (IK-Test) - Toleranzanalyse - Schwerpunktsimulation - Schattensimulation, Sicht-Simulation - Schraubenberechnung - Topologiestudie - Schadensanalyse Wir erstellen für Sie virtuelle Prototypen und interpretieren das Ergebnis. Richtig.
Spektroradiometer UVpad E: Natančna spektralna UV merjenja - Spektrometer

Spektroradiometer UVpad E: Natančna spektralna UV merjenja - Spektrometer

The UVpad E combines the benefits of the spectral measuring technology with a handheld and easy to operate radiometer. The UVpad E is technically based on our successful radiometer UVpad. With the external sensor and an optimized programming, it is even more precise and easier to operate. Use the spectroradiometer UVpad E for an accurate measurement of the UV irradiance and for comparisons of different UV lamps and UV LEDs. 512 photodiodes measure the spectrum in the wavelength range of 240 – 480 nm. The categorization in UVA, UVB and UVC is taken according to international standards and traceable. The calibration to only one light source is omitted. Spectral range:240 - 480 nm ± 5 nm Spectral bandwidth:2 nm Pixel distance:~0,5 nm Irradiance meas. range (typ.):2 - 5000 mW/cm² Irradiance meas. range (high power version):25 - 20000 mW/cm²
Merilni Most - Digimes Univerzalen

Merilni Most - Digimes Univerzalen

Die Digimes Universel ist eine 5 KHz-Trägerstrombrücke für ohmsche, induktive oder differentielle Transformatorwandler in Voll- oder Halbbrückenschaltung. Die Empfindlichkeit ist durch den Benutzer zwischen 2 mV/V und 100 mV/V entsprechend sechs Messbereichen einstellbar. Verstärkung und Offset können mit Potentiometern eingestellt werden, um die Kalibrierung des Sensors zu ermöglichen. Es gibt auch das Digimes Compact, das einem Sensor gewidmet ist.
FFT Analizni Modul

FFT Analizni Modul

Das Spektrum (FFT) macht sämtliche Schwingungskomponenten im Positionssignal der TX-Elektronik sichtbar. Dies ermöglicht die Visualisierung von Grund- und Oberschwingungen. In der Einkanalversion erstreckt sich der Frequenzbereich bis 19 kHz. Damit ist der akustische Bereich weitgehend gedeckt. Die Abbildung zeigt das Frequenzspektrum einer obertonarmen Stimmgabel. Neben der Visualisierung werden die Schwingungskomponenten bis zu einem definierten Grenzwert auch ausgewertet. Deutlich zu erkennen ist die Hauptschwingung mit 49 µm, als auch die zweite und dritte harmonische Schwingung mit 250 nm bzw. 100 nm. Wie beim Modul Oszilloskop kann das Spektrum als Bild- und Text-Datei exportiert werden.